Home About Us News ∣ Products Contact Us                                                                                          Demo
 
Gas Extinguishers Panel                                                                                        

Model No: SE 300 GAS EXTINGUISHERS PANEL (CE)
•Main Voltage: 230VAC (50Hz/60Hz) +15%, -10%
•Charger Voltage: 25~30VDC (Set Internally to 27.60V)
•Battery Space: 7.0 AH maximum
•Main Supply Protection: 1.5 AF 20 x 5 mm glass fuse
•Battery & Charger Voltage Protection: 1.5 AF 20 x 5 mm glass fuse
•Reverse Battery Protection: Battery Fuse
•Sounder Output(1" and 2" stage): 24VDC normal
•Sounder Output Protection: 500mAF 20 x 5 mm glass fuse
•Auxiliary Supply Output: 24VDC nominal
•Auxiliary Supply Protection: 500mAF 20 x 5 mm glass fuse
•Auxiliary Relay Contacts(1" and 2 Stage): 30VAC /DC 1.0A each
•Bottle Output: 24VDC nominal
•Bottle Output Protection: 500mAF 20 x 5 mm glass fuse
•Zone Voltage: 24VDC
•Quiescent Zone Current: 8mA per circuit
•Max Zone Circuit Resistance: 50Ω
•Max Sounder Circuit Resistance: 25Ω
•Max Resistance other Circuit: 50Ω
•Quiescent Battery Current (Tone Muted): 100mA nominal
•Quiescent Bat Current (Tone Muted): 125mA nominal
•Max Total Load Current: 1.5A (Although Each may be to fuse rating)
•Circuits Monitored for O/C and S/C: Bottle output, 1st and 2 st stage snd outputs, Zones 1 and 2.
•Circuits Monitored for O/C only: Hold/Abort, Auto/Manual, Gas fired, and Manual release. (S/C gives active condition although a resistance of up to 500Ω will still give an active condition)
•Color: DARK GREY Color
Standard Plate: With SAFETEK Logo+Brand
Catalog Download
All Specifications :


                                                                                                                                                                                                  

Model No: SE 300 (Red)  GAS EXTINGUISHERS PANEL (CE)
•Main Voltage: 230VAC (50Hz/60Hz) +15%, -10%
•Charger Voltage: 25~30VDC (Set Internally to 27.60V)
•Battery Space: 7.0 AH maximum
•Main Supply Protection: 1.5 AF 20 x 5 mm glass fuse
•Battery & Charger Voltage Protection: 1.5 AF 20 x 5 mm glass fuse
•Reverse Battery Protection: Battery Fuse
•Sounder Output(1" and 2" stage): 24VDC normal
•Sounder Output Protection: 500mAF 20 x 5 mm glass fuse
•Auxiliary Supply Output: 24VDC nominal
•Auxiliary Supply Protection: 500mAF 20 x 5 mm glass fuse
•Auxiliary Relay Contacts(1" and 2 Stage): 30VAC /DC 1.0A each
•Bottle Output: 24VDC nominal
•Bottle Output Protection: 500mAF 20 x 5 mm glass fuse
•Zone Voltage: 24VDC
•Quiescent Zone Current: 8mA per circuit
•Max Zone Circuit Resistance: 50

•Max Sounder Circuit Resistance: 25

•Max Resistance other Circuit: 50

•Quiescent Battery Current (Tone Muted): 100mA nominal
•Quiescent Bat Current (Tone Muted): 125mA nominal
•Max Total Load Current: 1.5A (Although Each may be to fuse rating)
•Circuits Monitored for O/C and S/C: Bottle output, 1st and 2 st stage snd outputs, Zones 1 and 2.
•Circuits Monitored for O/C only: Hold/Abort, Auto/Manual, Gas fired, and Manual release. (S/C gives active condition although a resistance of up to 500Ω will still give an active condition)
•Color: Red Color
Standard Plate: With SAFETEK Logo+Brand
Catalog Download

All Specifications :