Home About Us News ∣ Products Contact Us                                                                                         
 
Addressable Fire Alarm System                                                         

Model No: RCL-3100-1~8 (Addressable Fire Alarm Control Panel) (CE)
Capacity: 1 ~8 loops, up to 300 sensors and modules per loop
Input power: AC220V50 Hz
Battery power: DC24V 4Ah at least
Resistance of cable: Resistance of signaling wire <20Ω; insulation resistance >2MΩ@500V
Alarm delay time: 0 ~ 40 seconds
Operating temp/ humidity: 0°C ~ 50°Crelative humidity <95% (non-condensing)
Material of case: Steel, 1.2mm thickness
Dimensions: 1~4 loops: 500x600x150 ; 5~8 loops: 500x1000x150 (WxHxD, mm)
Optional: Thermal printer, Custom graphics, Voice evacuation, Remote annunciator
Standard Plate: With SAFETEK Logo+Brand
 
All Specifications : Catalog Download
 
                                                                                                                                                                                                  

Model No: RCL-280 (Addressable Smoke Detector) (CE)
Operating Voltage: DC 18V ~ 30V
Quiescent current: 1.7 mA / DC 24V
Alarm current: 15mA / DC 24V
Alarm response threshold: 15% during 30 seconds
LED indicator: Normal: flash one time per 6 seconds; Alarm: always on
Operating temp/ humidity: 0°C ~ 50°C
Relative humidity: < 95% RH, non-condensing
Material / color: Fire-proof plastic / White
Dimensions : Φ102 x 52 mm
Standard Plate: With SAFETEK Logo+Brand
 
All Specifications : Catalog Download
 
                                                                                                                                                                                                 

Model No: R-CM (Monitoring/Control Module)
Operating Voltage: DC18V ~ 30V
Monitor current: 1.5mA (typical) @ DC24V
Alarm current: 12mA (maximum) @ DC24V
LED indications: Normal: flash one time per 6 seconds; Alarm: always on
EOL resistor: 10KΩ1/4W
Operating temperature: 0°C ~ 50°C,
Relative humidity: < 95% RH, non-condensing
Dimensions: 60x76x32 (WxHxD, mm)
Standard Plate: With SAFETEK Logo+Brand
 
All Specifications : Catalog Download
 
                                                                                                                                                                                                  

Model No: RCL-183 (Addressable RoR Heat Detector) (CE)
Operating Voltage: DC 18V ~ 30V
Quiescent current: 1.5 mA / DC24V
Alarm current: 15mA / DC 24V
Alarm temperature: Rise up 30°C during 30 seconds
LED indicator: Normal: flash one time per 6 seconds; Alarm: always on
Operating temp/ humidity: 0°C ~ 50°C
Relative humidity: < 95% RH, non-condensing
Material / color: Fire-proof plastic / White
Dimensions : Φ102 x 47 mm
Standard Plate: With SAFETEK Logo+Brand
 
All Specifications : Catalog Download

                                                                                                                                                                                                

Model No: RCL-181 (Addressable Heat Detector) (CE)
Operating Voltage: DC 18V ~ 30V
Quiescent current: 1.5 mA / DC24V
Alarm current: 15mA / DC 24V
Alarm temperature: 70°C
LED indicator: Normal: flash one time per 6 seconds; Alarm: always on
Operating temp/ humidity: 0°C ~ 50°C
Relative humidity: < 95% RH, non-condensing
Material / color: Fire-proof plastic / White
Dimensions : Φ102 x 50 mm
Standard Plate: With SAFETEK Logo+Brand

All Specifications : Catalog Download


                                                                                                                                                                                                  

Model No: RM-PNT (Micro Panel Printer)
Printing method: Thermal dot line
Printing speed: Thermal paper
Paper width: 57.5 ± 0.05 mm
Paper thickness: 0.06 to 0.07 mm
Paper roll diameter: Max. 30 mm
Operating temp/ humidity: 0°C ~ 50°Crelative humidity <95% (non-condensing)
Color: Black
Dimensions: 82x58 (WxH, mm)
Standard Plate: With SAFETEK Logo+Brand

All Specifications : Catalog Download


                                                                                                                                                                                                  

Model No: RC-1W (Addressable Manual Call Point)
Operating Voltage: DC 18V ~ 30V
Quiescent current: 1.2 mA / DC24V
Alarm current: 10mA / DC 24V
LED indicator: Normal: flash one time per 6 seconds; Alarm: always on
Operating temp/ humidity: 0°C ~ 50°C
Relative humidity: < 95% RH, non-condensing
Material / color: Fire-proof plastic / White
Dimensions : Φ140 x 50 mm
Standard Plate: With SAFETEK Logo+Brand

All Specifications : Catalog Download


                                                                                                                                                                                                  

Model No: RD-109RLC (Addressable Manual Call Point)
Operating Voltage: DC 24V
Quiescent current: 1.2 mA / DC24V
Alarm current: 10mA / DC 24V
LED indicator: Normal: flash one time per 6 seconds; Alarm: always on
Operating temp/ humidity: 0°C ~ 50°C
Relative humidity: < 95% RH, non-condensing
Material / color: Fire-proof plastic / White
Dimensions : 92(H) x 92(W) x 48(D) mm
Standard Plate: With SAFETEK Logo+Brand

All Specifications : Catalog Download


                                                                                                                                                                                                  

Model No: RK624 (Addressable Fire Alarm Bell)
Operating Voltage: DC 24V
Quiescent current: 1.2 mA / DC24V
Alarm current: 30mA / DC 24V
Operating temp/ humidity: 0°C ~ 50°C
Relative humidity: < 95% RH, non-condensing
Material / color: Fire-proof plastics / Black
Dimensions : 150Φx 58(D) mm
Standard Plate: With SAFETEK Logo+Brand

All Specifications : Catalog Download


                                                                                                                                                                                                  

Model No: RC624 (Addressable Fire Alarm Bell)
Operating Voltage: DC 24V
Quiescent current: 1.2 mA / DC24V
Alarm current: 25mA / DC 24V
Operating temp/ humidity: 0°C ~ 50°C
Relative humidity: < 95% RH, non-condensing
Material / color: Fire-proof plastics / Black
Dimensions : 150Φx 65(D) mm
Standard Plate: With SAFETEK Logo+Brand

All Specifications : Catalog Download