  Home About Us News  Products Contact Us                                                                                          Demo
@
Fire Detector (Remote LED)          
                                                                                                                                                                                                  

EModel: SCL-280L (PHOTOELECTRIC SMOKE DETECTOR) (CE)
EVoltage: DC- 16~32V (DC-24V, 3WIRE) (-R)
EAlarm Current: 100mA maximum
EStandby current: 60uA average, 90uA peak at 24VDC
EEnvironmental temperature: 32 to 140 degrees Fahrenheit
EHumidity: 0 to 95% RH
EDetector sensitivity: nominal set at 10%/50cm
ESpecial Function: Can Connect to Remote Indicator (Wire to HCL-208, HC-301 Light)
EPower Connector: Don't direct contact DC-24V, need connect Fire control panel
EStandard: With SAFETEK Logo+Brand
All Specifications :

                                                                                                                                                                                                  

EModel: SCL-280EL (E Type PHOTOELECTRIC SMOKE DETECTOR) (CE)
EVoltage: DC- 16~32V (DC-24V, 3WIRE, White Color) (-R)
EAlarm Current: 100mA maximum
EStandby current: 60uA average, 90uA peak at 24VDC
EEnvironmental temperature: 32 to 140 degrees Fahrenheit
EHumidity: 0 to 95% RH
EDetector sensitivity: nominal set at 10%/50cm
ESpecial Function: Can Connect to Remote Indicator (Wire to HCL-208, HC-301 Light)
EPower Connector: Don't direct contact DC-24V, need connect Fire control panel
EStandard: With SAFETEK Logo+Brand
All Specifications :
                             
                                                                                                                                                                                                  

EModel: SCL-280CL (COMBINATION SMOKE AND HEAT DETECTOR) (CE)
EVoltage: DC- 16~32V (DC-24V, 3WIRE) (-R)
EAlarm Current: 100mA maximum
EStandby current: 60uA average, 90uA peak at 24VDC
EEnvironmental temperature: 32 to 140 degrees Fahrenheit
EHumidity: 0 to 95% RH
EDetector sensitivity: nominal set at 10%/50cm
ESpecial Function: Can Connect to Remote Indicator (Wire to HCL-208, HC-301 Light)
EPower Connector: Don't direct contact DC-24V, need connect Fire control panel
EStandard: With SAFETEK Logo+Brand

@
All Specifications :
                                           
                                                                                                                                                                                                  

EModel: SCL-181HL (FIXED HEAT DETECTOR) ( CE )
EVoltage: DC- 16~32V (DC-24V, 3WIRE) (-R)
EAlarm Current: 100mA maximum
EStandby current: 60uA average, 90uA peak at 24VDC
EEnvironmental temperature: 32 to 140 degrees Fahrenheit
EHumidity: 0 to 95% RH
EDetector sensitivity: nominal set at 10%/50cm
ESpecial Function: Can Connect to Remote Indicator (Wire to HCL-208, HC-301 Light)
EPower Connector: Don't direct contact DC-24V, need connect Fire control panel
EStandard: With SAFETEK Logo+Brand
All Specifications :
                                               
                                                                                                                                                                                                 

EModel: SCL-182L (RATE OF RISE HEAT DETECTOR) ( CE )
EVoltage: DC- 16~32V (DC-24V, 3WIRE) (-R)
EAlarm Current: 100mA maximum
EStandby current: 60uA average, 90uA peak at 24VDC
EEnvironmental temperature: 32 to 140 degrees Fahrenheit
EHumidity: 0 to 95% RH
EDetector sensitivity: nominal set at 10%/50cm
ESpecial Function: Can Connect to Remote Indicator (Wire to HCL-208, HC-301 Light)
EPower Connector: Don't direct contact DC-24V, need connect Fire control panel
EStandard: With SAFETEK Logo+Brand
All Specifications :
                                                                
@
                                                                                                                                                                                                 

EModel: SCL-181L (FIXED HEAT DETECTOR) ( CE )
EVoltage: DC- 16~32V (DC-24V, 3WIRE) (-R)
EAlarm Current: 100mA maximum
EStandby current: 60uA average, 90uA peak at 24VDC
EEnvironmental temperature: 32 to 140 degrees Fahrenheit
EHumidity: 0 to 95% RH
EDetector sensitivity: nominal set at 10%/50cm
ESpecial Function: Can Connect to Remote Indicator (Wire to HCL-208, HC-301 Light)
EPower Connector: Don't direct contact DC-24V, need connect Fire control panel
EStandard: With SAFETEK Logo+Brand
All Specifications :